Sign In | Join Free | My phrmg.org
China MOORE AUTOMATION LIMITED logo
MOORE AUTOMATION LIMITED
MOORE AUTOMATION LIMITED COVID-19 - Moore Automationare still working and able to shipping worldwide Best Price , Fast Shipping , New Products , Good Reputation !
Verified Supplier

8 Years

Home > Automation DCS >

FISHMAN LDS9000-3 LDS90003 LDS9000 3

MOORE AUTOMATION LIMITED
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment

FISHMAN LDS9000-3 LDS90003 LDS9000 3

Brand Name : FISHER

Model Number : LDS9000-3

Certification : CO.CQ

Place of Origin : USA

MOQ : 1

Price : inquiry

Payment Terms : T/T

Supply Ability : 10 pieces a day

Delivery Time : today

Packaging Details : new and original with factory sealed

Manufacture Year : 2016

Control System : FANUC

Application : Nuclear Power Plant

lead time : in stock

description : LDS9000-3 LDS90003 LDS9000 3

Weight : 4lbs

Contact Now

FISHMAN LDS9000-3 LDS90003 LDS9000 3

Product Description:

Advanced multi-processor design for leading-edge velocity loop bandwidth, fully digital current, velocity, and position loopsLarge-scale integration with custom ASICs and IPMs for performance and reliabilityA 16-bit A/D convertor for precise velocity command input Flash memory for simple field upgrades A

personality module to store setup parameters and simplify drive replacement Reduced component count for reliability Internally-shielded filters for electromagnetic compatibility (EMC) Four dedicated I/O plus eight user-selectable, optically isolated digital inputs and outputs (sourcing/active high):Two dedicated

inputs Two dedicated outputs Four user-selectable inputs Four user-selectable outputs Two analog inputs for external current limit Two analog outputs for variable monitoring or torque sharing The purpose of this manual is to provide the user with the necessary information to install, program, start up and

maintain the Bulletin 1305 drive. To assure successful installation and operation, the material presented must be thoroughly read and understood before proceeding. Particular attention must be directed to the ATTENTION and Important statements contained within.

Contact Information:

Contact:Miya ( manager)

Email :sales@mooreplc.com
Q Q: 2851195450
Skype: miyazheng520
Mobile:86-18020776792 ( what's app )

Related Product Recommendation:

MVI46-MNET DV47L250LE4A P326M-250LE4A MA-0186-100
MVI56-ADM MSD013A1Y LE4-116-XD1
MVI56-CSC MSD5AZA1Y PS416-INP-401
MVI56-DFCM PANADAC-332A P332AZ1.5KW APP-PFB-PCIE PCIE1500PFB 112011-5026
MVI56-DFCMR Jan-03 777978-VM
MVI56-HART BLX150F-FICO-4 MP3-404HR2
MVI56-MCM BLX150F-FICO-5 FRN1420A
MVI56-MCMR C3S075V4F10 I20 T40 M11 MVME162-220
MVI56-MNET COMPAX-S CPX8541S/F4 MVME2304 64-W5206C01B
MVI56E-GSC CPX2500S MVC4-TCB
MVI56E-MCM CPX2500S COMPAX-S B-SAIMP-XROHS
MVI56E-MNET HSSI-ED2 MCS20-230/24
MVI56E-MNETCR POP12 MYCOM IMS500-120AL
MVI56E-MNETR MTAP2 PCB-00322-REVD CMX45
MVI69-ADM C-5 VER.3 A702699T NDR096RTP871 X0417 PCB
MVI69-ADMNET COM5V2 X0420 B 105A 87-3 NDR096RTP865 PCB
MVI69-MCM KNS 51.14-2D Y6XC24 NDR064RTP869 PCB
MVI69-MNET D-35614 Y6ZA08 R8520 NDR064RTP86Z
MVI69-PDPMV1 D-35614 PKR 251 Y72A03 R8520 NDR064RTP872
MVI69-PDPS 4535 670 73831 4535 670 06391 DPM-GS-2GW-S
MVI71-ADM 9.40622E+11 A413125 AIU8
MVI71-AFC IBS RT 24 DIO 16/16-T A413135 AOU4
MVI46-MCM IBS RT 24DI /16-T A413160 FIU1
GLFPF3000VMF4 IBSS5DSC/I-T 2752000 A413280 CPR1
581B363B RFC 430 ETH-IB 2730190 A413285 BIR82
AT-GPIB-TN OCX-CTN-13-R-D-ST-ACV A413294 BOR86
PCI-6224 OCX-CTN-85-R-D-ST-24V A413295 AIR8C

The ground conductor of the motor cable should be connected to the drive ground (GRD) terminal directly. Connecting this ground conductor to a cabinet ground point or ground bus bar may cause high frequency current to circulate in the ground system of the enclosure. The motor end of this ground


conductor must be solidly connected to the motor case ground. Shielded or armored cable may be used to guard against radiated emissions from the motor cable. The shield or armor should be connected to the drive ground terminal and the motor ground as outlined in the Grounding section of this Installation


chapter. Common mode chokes are recommended at the drive output to reduce the common mode noise. An RFI filter can be used and in most situations provides an effective reduction of RFI emissions that may be conducted into the main supplylines. If the installation combines a drive with sensitive

devices or circuits,it is recommended that the lowest possible drive PWM frequency be programmed.

FISHMAN LDS9000-3 LDS90003 LDS9000 3

After starting RSLogix 5000 and either starting a new project or opening an existing project, make sure
that you are OFFLINE with the ControlLogix processor. I/O configuration is only available when offline.
If you have not already defined the contents of your ControlLogix chassis under your project's "I/O
Configuration" folder, you will need to define the ControlNet bridge module at a minimum. Use the right
mouse button to click on the "I/O Configuration" folder, then choose "New Module" from the pop-up menu.From the dialog box that appears, choose the ControlNet bridge of the type (1756-CNB or 1756-CNBR)and series that you are using. In the next screen, you will need to name the ControlNet bridge and
indicate its position in the ControlLogix chassis (slot 0 is the leftmost).After defining the ControlNet bridge, use the right mouse button to click on the ControlNet bridge under"I/O configuration", then choose "New Module" from the pop-up menu

SMC CDQ2B140C-J0406-XC Air Cylinder Hitachi 3-839273-^A New

SMC US447 24 Port Manifold Valve AMAT 0190-02046 Used Working

SMC SS0750-06-DAO00978 6-Port Pneumatic Manifold AMAT 4060-00846 New

SMC LZ-DUM02868 Actuator Controller Electric Cylinder LZ-XX0XC100 new 0190-33956

Hitachi 3-853222 SMC Air Cylinder CDQ2B40-30D-A73HS New

NEW SWAGELOK 6LVV-ALD6HFR4-P-CS-NV lots of 2

CHNT NB1-63 C1, NB1 CIRCUIT BREAKER

Tylan 2900 series MFC, FC-2900V, Ar, 500 SCCM, S9115

10 new AMAT 3090-00229 BoH Hexagon Head M5 x 3

ALTECH CORP. 8906.6 DIN RAIL FUSE MOUNT TERMINAL, TYPE SAK S3/35, 6675.2

Varian 06887001 Assembly Motor Drive Control

RT0300-2929 MECHANICAL ASSEMBLY

NEW Perlast 22-294910-00 Oring, white perlast, 3.989 x 0.070

VAT RECTANGULAR GATE, SLIT VALVE MONOVAT 0200X-AE24-1002, VARIAN M2000

Lot of 6 LITTELFUSE V251BA60, METAL OXIDE VARISTOR

Novellus 951479 Cable, motor power

Novellus 951337 Cable, motor power

2 PUV0047-5 power supply HOYA-SCHOTT, UV light source,

3 Banner D12SN6FP Fiber Optic sensor switch

Chemraz 9312-SC520, 2-312, Compound 520, 0.600 x 0.210 inch

Bearing, WFR Roller, MESA 2B-10-241, Used, Lot of 4

Nozzle FLT 80787-50 95Deg@500psi, Lot of two, New

7 RF Low freq silver plated connector AMP, 330830 = 5, 330830-8=2

SMC MDSUB7-90S-R73L Rotary Pneumatic Actuator AMAT 0520-00271 Lot of 2 New

SMC MY2HT16G-538-DCM1864M Rodless Cylinder Slide 3760-00353 new

SMC Manual Valve INA-24-63-04RD lot of 10 working

Hitachi S3-89146 SMC Air Cylinder CM2XL20-70 Qty 3 New

SMC IN587-07-A Gas Panel Communication Box 32-Port Manifold V114-5FZ-X6 Used

SMC REA32-Z2727-365 Pneumatic Sine Rodless Cylinder Lot of 3 Used

SMC In-Line Flow Bypass Valve VXD2150-06-1-X696 0190-34864 New

SMC 0190-18443 HE Thermal Fuse For Cold Loop New

SMC Digital Pressure Switch ISE5B-T2-26L ISE6B-A2-26L Lot of 8 Used Working

SMC NCDQ2B50-UIA980-090 Pneumatic Cylinder Lot of 3 Used Working

SMC KDM10-DUM02264 KDM One Touch Multiconnector AMAT 3300-13055 Lot of 8 New

SMC NCDQ2WB63-G0922-80 Pneumatic Cylinder Assembly Used Working

SMC 0010-26749 Gate Valve Actuator 300mm Rev. 002 Copper Exposed Used Working

BES-9239-33A SMC LPM Flow Switch Manual Valve AMAT 0910-28878 New

SMC NCDQ2B80-G0656-38 Pneumatic Cylinder Lot of 4 Used Working

SMC Thermo-Con High Lift Type Module INR-244-220A working

SMC 11GPM RAD 300 Flow Switch Assembly PF2W511-N10-1 New 0190-27970

SMC CDQ2B140C-J0406-XC Air Cylinder Hitachi 3-839273-^A New

SMC US447 24 Port Manifold Valve AMAT 0190-02046 Used Working

SMC SS0750-06-DAO00978 6-Port Pneumatic Manifold AMAT 4060-00846 New

SMC NCDQ2B50-UIA980090 Pneumatic Cylinder 3020-00317 lot of 4 working

The use of the product:

1.electronics manufacturing,

2.the elevator industry,


3.Experienced technichal support team.

Product's advantages:
1.provides integrated control, power, safety,
and information solutions for complete plant-wide control in a scalable,

2.Avoid unplanned downtime


3.textile printing and dyeing,

Our advantages:

1.Risk-free guarantee, 60 days refund. If the item you purchase from our store are not of perfected quality, simply return them to us for replacement or refund.


2.Avoid unplanned downtime


3.365 days warranty for all the goods from us.

Frequently Asked Questions:

1.Q:What about your lead time ?
A: We have many itmes in stock , 3-5 days you will receive it .

2.Q: What is the capacity of your warehouse?
A: We have 1-2Mil USD safe stocks and 3 warehouses, which located Xiamen, Shenzhen & Hongkong.

3.Q:How long warranty does Moore can provide ?
A: Moore can provide 1 year warranty !

Send your Inquiry details in the Below, Click "Send" Now!



Product Tags:

sst pb3 clx rll

      

dcs modules

      
 FISHMAN LDS9000-3 LDS90003 LDS9000 3 Manufactures

FISHMAN LDS9000-3 LDS90003 LDS9000 3 Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: MOORE AUTOMATION LIMITED
*Subject:
*Message:
Characters Remaining: (0/3000)